Product Paramenters
Model | BK-D560 | BK-D580 | BK-D590 | ||
Optical System | Double Beam, Grating 1200 lines/mm | ||||
Wavelength Range | 190~1100nm | ||||
Spectral Range | 1.8nm | 1nm | 0.5,1,2,4,5nm | ||
Wavelength Accuracy | ± 0.3nm | ||||
Wavelength Repeatability | ≤ 0.2nm | ||||
Photometric Accuracy | ± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.3% T (0~100% T) | ||||
Photometric Repeatability | 0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T) | ||||
Stray Light | ≤ 0.05 T @ 360nm; 220nm | ||||
Stability | ± 0.0008A / h @ 500nm | ||||
Baseline Flatness | ± 0.0005A | ||||
Noise | ± 0.0002Abs | ||||
Display | 65 thousand true color 7 inch TFT LCD(480 *800) | ||||
Photometric Mode | T, A, C, E | ||||
Photometric Range | 0~200% T,-0.301~3.0A | ||||
Detector | Silicon Photodiode | ||||
Light Source | Deuterium Lamp, Tungsten Lamp | ||||
Input | Membrane Keypad | ||||
Output | USB Print and data output, Connect PC | ||||
Standard Accessories | 10mm glass cuvette *4 units 10mm quartz cuvette *2 units,software | ||||
Optional Accessories | Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system | ||||
Power Supply | AC110V/220±10%, 60/50Hz | ||||
Packing Size(mm) | 740*570*440 | ||||
Gross Weight(kg) | 25 |
Features
Features:
⊙Environmental Deuterium lamp, preventing from Ozone inhalation
⊙Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp
⊙Socket-Type Deuterium lamp and Tungsten lamp
⊙GLP self-check function:check the wavelength accuracy and Photometry accuracy,provide test report and power-off protection
⊙Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
⊙Si02 coating optical mirror, reduces the influence from outside
Basic Functions:
1, Photometry
Test Abs., Transmittance and Energy by fixed wavelength
2, Quantitative
Linear fit and Linear fit through zero two modes
a.Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve
1. Establish A=K1*C+K0, can search original data, graph curve, parameters settings
2. Can save 240 group curves, can test 240 data in each curve
3. Double wavelength, Triple wavelength test functions.
3, Kinetics
Used for time course scanning or reaction rate calculations△A/t, can search all data
4, Multi-Wavelength
Can test Transmittance and Abs. with 8 different wavelengths at most
5, Scanning
User can set the scan range from 190nm to 1100nm to test the max. Abs. peak value, can do derivation,arithmetical operationsto the graph.
6, Biology
6 methods: DNA/Protein, UV, Lowry, BCA,CBB and Biuret
⊙Environmental Deuterium lamp, preventing from Ozone inhalation
⊙Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp
⊙Socket-Type Deuterium lamp and Tungsten lamp
⊙GLP self-check function:check the wavelength accuracy and Photometry accuracy,provide test report and power-off protection
⊙Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically
⊙Si02 coating optical mirror, reduces the influence from outside
Basic Functions:
1, Photometry
Test Abs., Transmittance and Energy by fixed wavelength
2, Quantitative
Linear fit and Linear fit through zero two modes
a.Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve
1. Establish A=K1*C+K0, can search original data, graph curve, parameters settings
2. Can save 240 group curves, can test 240 data in each curve
3. Double wavelength, Triple wavelength test functions.
3, Kinetics
Used for time course scanning or reaction rate calculations△A/t, can search all data
4, Multi-Wavelength
Can test Transmittance and Abs. with 8 different wavelengths at most
5, Scanning
User can set the scan range from 190nm to 1100nm to test the max. Abs. peak value, can do derivation,arithmetical operationsto the graph.
6, Biology
6 methods: DNA/Protein, UV, Lowry, BCA,CBB and Biuret
Packing & Delivery
To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Company Profile
BIOBASE Group is a professional manufacturer of laboratory products since1999. Оur mаіn рrоduсtѕ аrе Віоѕаfеtу Саbіnеt (Сlаѕѕ І/П/Ш), Lаmіnаr FlоwCabinet, Fume Hood, Biochemistry analyzer, Reagent, Autoclave and Incubator.We have more than 2000 employees and 20000 square meters production base.Our output per year reaches 10000 units. Pursuing the highest quality is the tenet of BIOBASE. We hope everybody will enjoy BIOBASE service to keep away from the infectious disease.
After Sales Service
Related And Hot-selling Products
Contact Misha
Product Categories : Lab&Medical Equipment > Spectrophotometer
Other Products
Hot Products
Meditech Portable Lightweight Veterinary Fluid Warmer MD-T1Meditech Portable First-Aid Medical Aed Defi5s with Selectable EnergyChina Good Selling Cheap Disposable Infusion PumpHeart Rate Monitor with Smart SportFashion Sport Mult-Function Pulse OximeterWearable Device for Monitoring Blood OxygenNasal Spray Installed BottleNo Side Effects Rhinitis Medicine for Babies Physiological SeawaterChina Saline Nasal Spray for Adult with CE&ISO CertifiedDisposable SpO2 Sensor60ml Adult Nasal Spray50ml Physiological Seawater Pediatric Nasal SprayNellcor Neonate / Infant Wrap SpO2 Sensor/Probe CeapprovedBluetooth Six- Parameter OEM Module Pm6750 with Standard AccessoiesNasal Cleaner Physiological Seawater SprayProfessional Manufacturer 2.4 Inch Multi-Parameters Patient Monitor for Medical Equipment