Find Syringe Pump, Dual Syringe Pump, Electric Syringe Pump on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Emergency, operation and clinics apparatuses > Syringe Pump And Infusion Pump > Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFI

Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFI

Product Description

Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFI 

Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFI

 

Specification:
Dimension: 270mm*140mm*80mm(D x W x H)
Weight: 3 Kg
Power Adaptor rate voltage:
Main Power:~100V-240V,50/60Hz
Internal Battery: 10.8V Rechargeable lithium battery
Power Consumption: 100VA
Maximum Flow Rate: 2100(mL/h)

Essential Performance:

Channel number

2 Channel

 

 

 

Rate Range

2mL Syringe:0.01-100mL/h;

5mL Syringe:0.01-150mL/h;

10mL Syringe:0.01-400mL/h;

20mL Syringe:0.01-600mL/h;

30mL Syringe:0.01-1000mL/h;

50mL Syringe:0.01-2100mL/h;

All the above steps were performed at 0.01ml /h.

VTBI Range

0.01~9999.99mL,at step 0.01mL

Accuracy

±2%

 

 

 

Purge Rate(bolus Rate)

2mL Syringe: 1~100mL/h;

5mL Syringe: 1~150mL/h;

10mL Syringe: 1~400mL/h;

20mL Syringe: 1~600mL/h;

30mL Syringe: 1~1000mL/h;

50mL Syringe: 1~2100mL/h;

All the above step at 1mL/h.

 

KVO Rate

3mL for Rate10ml/h

1mL for 1ml/h ≤ Rate < 10ml/h

KVO Rate = Settinge Rate < 1ml/h

Time setting range

00h00min~99h59minat step 1min

 

Occlusion pressure

Maximum:130kPa ± 30kPa, Minimum: 26kPa ±

20kPa,level 9 continuously adjustable,See 7.4.7

for setting of occlusion pressure level

Mode

Eight Modes: R+VR+TV+TR, Drug library,

WeightRelay modeGradient mode.

Syringe size

2mL,5mL,10mL,20mL,30mL,50mL

Battery operating time at intermediate rate

Battery can run continuously for more than 3 hours after being fully charged.

 

Wifi

a)Carry out data transmission through WiFi with

"WiFi debugging" app;

 b)The user access control adopts the account

password system and refuses to log in illegally.

Maximum infusion pressure

160kPa

 

 

 

 

Time to activate the occlusion alarm; max bolus (Essential Performance)

 

Minimum rate: Occlusion alarm pressure is

26kPa±20kPa, time is < 1h; Occlusion alarm

pressure is 130kPa±30kPa, time is <3h30min.

Medium rate: Occlusion alarm pressure is 26kPa ±20kPa, time<15min, bolus volume is less than 1mL; Occlusion  alarm pressure is 130kPa±30kPa, time<45min, bolus volume is less than 2mL.

(Create a occlusion point in one Meter from outlet

of syringe)

 

Feature:

Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFI

 

Related Products

Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFI

 Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFI

Hospital Electric Touch Screen Dual Channel Syringe Pump with WIFIHospital Electric Touch Screen Dual Channel Syringe Pump with WIFIHospital Electric Touch Screen Dual Channel Syringe Pump with WIFI

Contact us if you need more details on Syringe Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Dual Syringe Pump、Electric Syringe Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Emergency, operation and clinics apparatuses > Syringe Pump And Infusion Pump

Premium Related Products